Fan Coil Unit, Ceiling Ducted Fan Coil Unit, Horizontal Concealed Fan Coil manufacturer / supplier in China, offering 4 Pipe Ceiling Ducted Fan Coil Unit with Plenum Box, Huali 10HP Water Cooled Industrial Water Chiller Water Cooler, Residential Fresh Air Dehumidification (55L/D dehumidifer) * and so on.

(/ )

Supplier Homepage Product Fan Coil Unit & Air Handling Unit 4 Pipe Ceiling Ducted Fan Coil Unit with Plenum Box

4 Pipe Ceiling Ducted Fan Coil Unit with Plenum Box

FOB Price: US $79-199 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $79-199/ Piece
Get Latest Price
Production Capacity: 3000/Month
Transport Package: Carton Case
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HLC
  • Air Tube Material: Galvanized Sheet
  • Operating Voltage: 230 VAC
  • Application Fields: Food Processing
  • Lifetime: 5~10 years
  • Condition: New
  • Air Flow: 200~1400cfm
  • Heating Capacity: 3251~22137W
  • Thermostat: Optional
  • Specification: 980*500*260mm
  • HS Code: 8415909010
  • Type: Fan Coil Unit
  • Corrosion Durability: Ultrahigh
  • Noise Level: Low
  • Mounting: Ceiling Mount
  • Certification: CE
  • Name: Ceiling Ducted Fan Coil Unit
  • Cooling Capacity: 2247~13965W
  • 2/3-Way-Valve: Optional
  • Trademark: HIGOLDEN
  • Origin: China
Product Description
4 pipe Ceiling ducted fan coil unit with plenum box

Description of Horizontal concealed fan coil unit, FCU:
1, Lightweight, compact, solid, and with ultra-thin design
2,Four-row pipes with hyperbolic shutter type aluminum fin heat exchanger, strengthens the air by impeller fan of large input air, so that the unit maximizes heat transfer efficiently. 3 cooling 1 cooling and 2 cooling and 2 heating for optional.
3, Particularly, the unit adopts large impeller slow-speed of revolution fan and low noise motor
With high, medium, and low wind speed in third gear, water system adopts room temperature control devices to adjust flexibly. When nobody is in the room, the fan stop automatically, economic and energy-saving
4, Each model has four kinds of overboard static pressures which are 0PA, 80PA, 60PA, and 80PA (optional)
5, Unit can achieve the overboard static pressure by only updating the motor connector plug
6, Controlled easily by subarea in accordance with the application and room design air-conditioning system into several zone system.

Parameter of horizontal concealed fan coil unit
Horizontal Concealed Fan Coil
ModelHLC-34HCHLC-51HCHLC-68HCHLC-85HCHLC-102HCHLC-136HCHLC-170HCHLC-204HCHLC-238HC
Air flow (m 3 /h)High speed34051068085010201360170020402380
Medium speed2553835106387651020127515301785
Low speed17025534042551068085010201190
cooling capacityHighW22473146414650565955775896571160113965
BTU76691073714150172562032426478329593959447663
MediumW1620244032904120485065508190973011580
BTU5529832811229140621655322355279523320839523
LowW131020102650332039005300661078609350
BTU447168609044113311331118089225602682631912
heating capacityHighW3251469761897747949111997147321816222137
BTU110961603121123264413239340946502806198775554
MediumW235035204530604068509260117401414016360
BTU80211201415461206152337931604400694826055837
LowW1620247031304170474065008180971011290
BTU5529843010683142321617822185279183314038533
surplus pressure of outlet (Pa)Normal0 or 12
High static pressure30 or 50
Cooling water temperature7 to 12 degree
Hot water temperature40 to 60 degree
Power supplyAC220V/50Hz
Heat ExchangerTypecopper pipes covered into aluminum fins, fin pitch 2.2mm
Water supply kg/h3244826558149361278160219152178
Water resistance kPa303030304040404050
Working pressure1.6MPa
Low static
pressure FCU
Input power w3752627696134152189228
Motor power w101620253020×225×230×240×2
High static
pressure FCU
Static pressrue
30Pa
Input power w44597287108156174212253
Motor power w122025304025×230×240×250×2
Static pressure
50Pa
Input power w496684100118174210250300
Motor power w162530405030×240×250×260×2
Fan motor quantity122223444
Noise
dB(A)
Low static pressure≤37≤39≤41≤43≤45≤46≤48≤50≤52
High static pressure 30Pa≤40≤42≤44≤46≤47≤48≤50≤52≤54
High static pressure 50Pa≤42≤44≤46≤47≤49≤50≤52≤54≤56
Pipe Inlet/outlet water pipeZG3/4 "internal thread
Condensation water pipeZG3/4" external thread
DimensionL mm780880980108011801480168017801880
W mm500500500500500500500500500
H mm260260260260260260260260260
20GP container loading quantity325290260236216172152143135
40GP container loading quantity666591531482441351309292277

Photos of ceiling ducted fan coil unit
4 Pipe Ceiling Ducted Fan Coil Unit with Plenum Box
4 Pipe Ceiling Ducted Fan Coil Unit with Plenum Box
4 Pipe Ceiling Ducted Fan Coil Unit with Plenum Box4 Pipe Ceiling Ducted Fan Coil Unit with Plenum Box
 
Send your message to this supplier
Avatar
Ms. Aysha
Manager
*From:
To: Ms. Aysha
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now