Gold Member Since 2008
Audited Supplier
Shenzhen Jinhuali Refrigeration Plant Co., Ltd.

Fan Coil Unit, Air Cooler, Vertical Exposed Type Fan Coil manufacturer / supplier in China, offering Low Noise Vertical Fan Coil Unit*, Energy Saving Air Cooled Rooftop Air Conditioner / Package AC, HVAC System Terminal Horizontal Concealed Fan Coil Unit and so on.

(/ )

Low Noise Vertical Fan Coil Unit*

FOB Price: US $99 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $99/ Piece
Get Latest Price
Production Capacity: 3000 Unit/ Month
Transport Package: Carton Packing
Payment Terms: L/C, T/T, Paypal, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HLC-34VE-238VE
  • Certification: CE
  • Usage: for Refrigerate
  • Certificate: CE
  • Power Supply: AC220V/50Hz
  • Specification: CE
  • HS Code: 8415909000
  • Cooling Method: Direct Cooling
  • Condition: New
  • Heating and Cooling: Heating and Cooling
  • Noise Level: Ultra Low
  • Trademark: HUALI
  • Origin: Guangdong
Product Description
Vertical Fan Coil Unit
1, Exquisite Structure, pleasing in appearance, reasonable product structure, fire insulation.
2, It has the fine design, light weight and good strength, also easy installation.
3, The effiency is high. Fan coil adopt seamless red Copper Pipe and aluminum blinds-fin. Mechanical expand tubes make sure the Close contact between fin and cooper pipe, reaching he best heat transfer. Before leaving factory strict test is done, so is the 100% pressure leak testing (20 kg/cm2 pressure leak test), to ensure product quality and performance.
4, It is easy to control and owns complete functions.
5. Ceiling Exposed, Ceiling Concealed, Floor Mounted, Cassette type for optional.

Specifications

Water Chilled Fan Coil Units, Concealed fan coil for duct installation both exposed version and concealed version available, LCD controller hydraulic fan coil
Air Flow: 340m3/h--2380m3/h.
Water chilled Fan Coil Units
Cooling capacity: 1.8kw--12.6kw
Model: HLC-34-238VE
Power supply: 220V/1PH/50HZ and 110V/1PH/60HZ
Characters
The HLC series water chilled fan coil units are designed specially to meet the varied requirements of zone cooling or heating using chilled water or hot water.
This unit is presented as a single block including: Fan deck, cooling and/or cooling coil, removable filter, drip tray, electrical connection box and decorative cabinet (excluded for concealed version).

OPTIONAL
L Condensation tray (water connection area)
L Different type thermostats with more advanced functions
Application:
Fan coil units is the indoor terminal units of the air conditioning system, . Applicable to hotels, villas, hospitals, cinemas, stadiums, recreations, office blocks, factories and so on.
Note:
1. The noise value is tested in all the mute indoor, under norm operation condition, the measuring point is 1 meter away in front of the unit and 1 meter below the unit.
2. Cooling capacity is tested under: Air inlet DB=27° C, WB=19.5° C, intake water temperature=7° C, outlet water temperature=5° C, and 3 column coil.
3. Heating capacity is tested under: Air inlet DB=21° C, intake water temperature 60° C, same water flow condition as testing cooling capacity, and 3 column coil.

Parameter of vertical exposed fan coil unit
Vertical Expose Fan Coil
ModelHLC-34VEHLC-51VEHLC-68VEHLC-85VEHLC-102VEHLC-136VEHLC-170VEHLC-204VEHLC-238VE
Air flow(m 3 /h)High speed34051068085010201360170020402380
Medium speed2553835106387651020127515301785
Low speed17025534042551068085010201190
cooling capacityHighW18002700360045005400720090001080012600
BTU6143921512287153591843024574307173686043004
MediumW1620244032904120485065508190973011580
BTU5529832811229140621655322355279523320839523
LowW131020102650332039005300661078609350
BTU447168609044113311331118089225602682631912
heating capacityHighW2700405054006750810010800135001620018900
BTU92151382318430230382764536860460765529164506
MediumW235035204530604068509260117401414016360
BTU80211201415461206152337931604400694826055837
LowW1620247031304170474065008180971011290
BTU5529843010683142321617822185279183314038533
Cooling water temperature7 to 12 degree
Hot water temperature40 to 60 degree
Power supplyAC220V/50Hz
Heat ExchangerTypecopper pipes covered into aluminum fins, fin pitch 2.2mm
Water supply kg/h3244826558149361278160219152178
Water resistance kPa303030304040404050
Working pressure1.6MPa
Low static
pressure FCU
Input power w3752627696134152189228
Motor power w101620253020×225×230×240×2
High static
pressure FCU
Static pressrue
30Pa
Input power w44597287108156174212253
Motor power w122025304025×230×240×250×2
Static pressure
50Pa
Input power w496684100118174210250300
Motor power w162530405030×240×250×260×2
Fan motor quantity122223444
Noise
dB(A)
Low static pressure≤37≤39≤41≤43≤45≤46≤48≤50≤52
High static pressure 30Pa≤40≤42≤44≤46≤47≤48≤50≤52≤54
High static pressure 50Pa≤42≤44≤46≤47≤49≤50≤52≤54≤56
Pipe Inlet/outlet water pipeZG3/4 "internal thread
Condensation water pipeZG3/4" external thread
DimensionL mm100010001200130014001600190021002100
W mm270270270270270270270270270
H mm645645645645645645645645645
20GP container loading quantity1891891581461351181009090
40GP container loading quantity373373311287267233196178178

Send your message to this supplier
Avatar
Ms. Aysha
Manager
*From:
To: Ms. Aysha
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now